Interpretation 90.1-2007-21 – Ma(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section 9.4.1.1 Exception c, regarding the exception where automatic lighting shutoff would endanger the safety or security of the room or building occupant(s).) Interpretation 90.1-2007-20 – Ma(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section 9.4.5, regarding facade lighting.) Interpretation 90.1-2007-19 – Ma(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section 9.2.2.3 Exception (a) and Section 9.6.2(a), regarding display or accent lighting in museums.) Interpretation 90.1-2007-18 – Ma(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section 6.4.3.9, regarding Ventilation Controls for High-Occupancy Areas.) Interpretation 90.1-2007-17 – Ma(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Sections G1.2, G3.1.1 and G3.1.2.10, regarding the modeling of HRV in Baseline HVAC Systems.) Interpretation 90.1-2007-16 – Ma(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section G3.1.1 and Table G3.1.1A, regarding Baseline HVAC Systems for mixed use buildings.) Interpretation 90.1-2007-15 – Ma(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section G3.1.1 and Table G3.1.1.A, regarding Baseline HVAC System Type.) Interpretation 90.1-2007-14 – Decem(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section G3.1.3.10, regarding Chilled-Water Pumps (System 7 & 8).) Interpretation 90.1-2007-13 – J(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Sections 9.5 and 9.6, Tables 9.5.1 and 9.6.1, regarding Baseline Lighting Power Density in Retail Banks.) Interpretation 90.1-2007-12 – J(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section 11.1.2, Table 11.3.1, and Table G3.1, regarding baseline and proposed simulations for compliance.) Interpretation 90.1-2007-11 – Ma(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Table G3.1.1A, regarding Baseline HVAC System Types.)

Interpretation 90.1-2007-10 – Ma(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section 5.4.3.4, regarding vestibules and Exceptions f and g.) Interpretation 90.1-2007-09 – Janu(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section G3.1.3.1, regarding heat pump operation.) and 9.4.1.2 and Appendix G (Table G3.1), regarding minimum lighting control requirements and Appendix G credit for lighting controls.) Interpretation 90.1-2007-08 – Octo(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Sections 9.4.1.1.

Interpretation 90.1-2007-07 – Octo(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Sections 5.8.2.4, 5.8.2.5 and A8, regarding U-factor and Solar Heat Gain Coefficient for fenestration.) Interpretation 90.1-2007-06 – Octo(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section 9.1.1, Exception (c), regarding the exception for health or safety lighting.)

#XSECTION 9.5 HOW TO#
Interpretation 90.1-2007-05 - Janu(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Sections G3.1.1 and Tables G3.1 and G3.1.1.A, regarding how to apply Exceptions a, b, c, and d in determining Baseline System for large warehouses.) Interpretation 90.1-2007-04 - Ma(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section 9.5.1 and Table 9.5.1, regarding building are type(s) and gross floor area used to calculate the interior lighting power allowance by the Building Area Method)

Interpretation 90.1-2007-03 - Octo(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section G3.1.2.2, regarding unmet load hours for the proposed design and baseline building designs.) Interpretation 90.1-2007-02 - Octo(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section 11.3.2, regarding HVAC system type and related performance parameters for the budget building design.) Interpretation 90.1-2007-1 - Octo(Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2007, Section 5.4.3.2, regarding exceptions to the mandatory provisions for air leakage for fenestration and doors.) NOTE: All documents linked from this page are in PDF-format.